Tender Name : | Main Contractor for the Electrical & Security Project at Ngunguru School |
Reference # : | 245296 |
Open Date : | Tuesday, 30 January 2024 9:00 AM (Pacific/Auckland UTC+13:00) |
Close Date : | Thursday, 29 February 2024 5:00 PM (Pacific/Auckland UTC+13:00) |
Department/Business Unit : | Board of Trustees - Approve by BoT - ie. School Principal |
Tender Type : | Request for Tenders (RFT) |
Tender Coverage : | Sole Agency [?] |
Categories : |
|
Regions: |
|
Exemption Reason : | None |
Required Pre-qualifications : | None |
Contact : |
All enquiries to be made through the GETS Question & Answer function |
Alternate Physical Delivery Address : | All communications through GETs question and answer function |
Alternate Physical Fax Number : | All submissions to be made through the GETS website |
The Contract Works required are:
Block 10A
• Room 11 & Senior MP Space – Upgrade lighting to LED inside and outside. Replace switchboard.
Block 2
• Reception – Upgrade switchboard with correct breakers. Replace correct frame.
• Resource Room – Upgrade switchboard to fit blanks, RCBO to lighting circuits, label correctly. Upgrade lighting to LED.
• Verandah – Upgrade camera power supply with appropriate weatherproof outlets. Install security lighting to west facing verandah.
• Room 6 – Upgrade lighting to LED inside and outside. Fit RCBO to lighting circuit.
Block 9A
• Library, Multipurpose, Kitchen, Laundry, Storage Rooms – Upgrade all lighting to LED. Upgrade switchboard.
Block 14
• Caretakers Shed – Upgrade lighting to LED. Upgrade wire to permanently cover TPS cabling to standard.
Block 16
• ANC 16: Toilets & Changing Rooms – Upgrade lighting to LED for security lighting. Replace broken sensor and fit cage for protection. Upgrade to RCBO to light circuits.
Block 17
• All Classrooms – Install power points for iPad power supplies (using multi-blocks). Install power points in cleaner’s cupboard. Replace outside sensor.
Block 1056/319
• Pump Shed (back of Block 15) & Site – Fit plate, mount RCD to power outlets. Upgrade/install all underground electricity signs.
• Site – Fit plate mount to RCD in Pump Shed. Upgrade all underground wires signs.