Main Building Contractor for Block H: Essential Infrastructure Work at William Colenso College

Details

Tender Closed
RFx ID : 28364795
Tender Name : Main Building Contractor for Block H: Essential Infrastructure Work at William Colenso College
Reference # : 231356
Open Date : Tuesday, 31 October 2023 9:00 AM (Pacific/Auckland UTC+13:00)
Close Date  : Thursday, 23 November 2023 5:00 PM (Pacific/Auckland UTC+13:00)
Department/Business Unit : Board of Trustees - Approve by BoT - ie. School Principal
Tender Type : Request for Tenders (RFT)
Tender Coverage : Sole Agency  [?]
Categories :
  • 72000000 - Building and Facility Construction and Maintenance Services
Regions:
  • Hawke's Bay
Exemption Reason : None
Required Pre-qualifications : None
Contact : All enquiries to be made through the GETS Question & Ansawer function
Alternate Physical Delivery Address  : All submissions to be made through the GETS website
Alternate Physical Fax Number  :
Agency Address : NEW ZEALAND
Overview

The Contract Works required are:
i. Nature of the Works:
Remove internal partitions and low ceilings in the corridor / toilet areas. Raise
walls to new roof structure over, subdivide with new walls / screens /doors to fit the
schools ILE and infrastructure requirements for the area.
Block H Interior
● Water ingress due to poor roofing junction between block E and H,
● Heating Baby Sleeping Rooms 114 and 115 –
● Back wall connecting to Block E (rationalised) –
● Remove and replace water ingress damaged wall joinery, gib and linings with new
gib, replace damaged timbers, insulate, replace autex,
● Install 2 x heat pumps Kindy Toilets
● Back wall connecting to Block E (rationalised)
● Remove and replace water ingress damaged wall joinery, gib and linings with new
gib, replace damaged timbers, insulate, replace permanent fittings Interior
● Water ingress due to poor roofing junction between block E and H
Block H Exterior
● Cladding failure,
● Roofing failure
● Replace cracking asbestos boards on the external cladding
● External-Cladding Outside Rooms 18, 12, 16 and 15, Replacement of external
cladding - ECC Wing-Corner of rooms H1 and H9. To be noted it may be asbestos.

● TPU Wing-Damaged external cladding on south side of the building. TPU Wing-
External cladding on northern wall up to 1m (where concrete path is),

● Replacement of rotting timber window framing,
● TPU - Partial replacement of roof, on existing battens, new roof underlay,
● New flashings and guttering and insulation.
● Repair of water ingress paths at the external air conditioning units.
● Re-pitch of roof section over baby sleepy rooms and kindy bathroom
Designing Quality Learning Spaces (DQLS)/Block Comfort
SECTION 1: Ventilation and air quality issues Lighting levels or glare Noise levels
or acoustics Heat/ Cold (thermal comfort)

RFx Outcome

No Winner